Home
Hall types Additional services
Uninsulated Warehouse Insulated warehouse Insulated production hall/ warehouse Insulated Manufacturing Hall

Insulated warehouse

One example from our various hall system is type TW 600 - TW 1200.

The hall can be varied and supplemented any way to suit your individual needs, for example by integrating domelights or lighting rows in the roof, lateral canopies, craneways etc.

The steel binder distance is 5 m, the roof pitch is 6° and the average heat transition coefficient km = 0.65 w/m²k
 
Insulated warehouse – Type TW 600 – TW 1200
Click to see more pictures.


Prices and additional information:


The following prices are gross list prices, plus VAT valid at that time (prices are valid for Germany).

We would be pleased to work out a detailed offer for your specific needs.

 
Please do not hesitate to contact us!
Back to Standard Halls

Hall type
External dimensions
W x L x H
Clear height
Eaves/ridge
Area
Lighting row
length
Basic cost
Additional services
Total price
TW 600 20,42 x 30,42 x 4,82 m 4,74 / 5,79 m 600 m² 28 m 108.000 €
69.000 € 12.400 € 17.100 €
206.500 €
TW 600 20,42 x 30,42 x 5,82 m 5,74 / 6,79 m 600 m² 28 m 115.600 €
69.000 € 12.400 € 17.400 €
214.400 €
TW 600 20,42 x 30,42 x 6,82 m 6,74 / 7,79 m 600 m² 28 m 125.700 €
69.000 € 12.400 € 17.900 €
225.000 €
TW 800 20,42 x 40,42 x 4,82 m 4,74 / 5,79 m 800 m² 38 m 132.500 €
85.600 € 13.800 € 19.000 €
250.900 €
TW 800 20,42 x 40,42 x 5,82 m 5,74 / 6,79 m 800 m² 38 m 141.800 €
85.600 € 13.800 € 20.200 €
261.400 €
TW 800 20,42 x 40,42 x 6,82 m 6,74 / 7,79 m 800 m² 38 m 154.300 €
85.600 € 13.800 € 20.700 €
274.400 €
TW 1000 20,42 x 50,42 x 4,82 m 4,74 / 5,79 m 1000 m² 48 m 156.500 €
102.000 € 15.700 € 22.100 €
296.300 €
TW 1000 20,42 x 50,42 x 5,82 m 5,74 / 6,79 m 1000 m² 48 m 167.400 €
102.000 € 15.700 € 23.400 €
308.500 €
TW 1000 20,42 x 50,42 x 6,82 m 6,74 / 7,79 m 1000 m² 48 m 182.300 €
102.000 € 15.700 € 23.400 €
323.400 €
TW 1200 20,42 x 60,42 x 4,82 m 4,74 / 5,79 m 1200 m² 58 m 181.000 €
118.800 € 17.500 € 32.400 €
349.700 €
TW 1200 20,42 x 60,42 x 5,82 m 5,74 / 6,79 m 1200 m² 58 m 193.700 €
118.800 € 17.500 € 33.000 €
363.000 €
TW 1200 20,42 x 60,42 x 6,82 m 6,74 / 7,79 m 1200 m² 58 m 211.000 €
118.800 € 17.500 € 34.000 €
381.300 €


Our services include:


General site plans/view plans/production plans, structural calculations for steel construction and foundation, foundation-/reinforcement-plans, heat insulation proof. The building owner has to bear the costs of the tests.

Steel construction (framework), galvanized, including anchor elements, for a snowload of 75 kg/m².

Thermal roof elements TL 75, 0.75 mm strong and Pladur-Z PVDF-coated on the weather side, underside coated with white protecting lacquer.

Roof draining by galvanized rectangular section eaves gutters and required fall-pipes

Wall cladding made of trapezoid steel sheets, 0.88 mm strong and coated on the outside with Pladur-Z, inside coated with white protecting lacquer, without concrete socle h= 0.25 m (see additional services: Earthwork, draining and reinforced concrete works)

 
Colours of the outside wall sheet metal according to colour choice of the manufacturer, as well as cover lids for thermal wall screw fitting without extra cost.

Preforms like hinged caps, front flashing, eaves flashing, gate- and door frames, closing elements etc.

Profile glazing glass h = 2.50 m, two-leaf type NP 5, one balanced window per frame element 1.05/1.05 m – except end elements

1 pce. Sliding gate 4 x 4 m made of double-wall aluminium profile, electric, with safety contact – not including electric installation (see additional services: Electric installation and lighting) – as well as two double-walled steel doors. 1 x 2 m

Assembly of all before mentioned parts and materials including required additional services

Construction according to present thermal insulation regulations and flat roof regulations. Subject to technical changes.